bims-orenst Biomed News
on Organs-on-chips and engineered stem cell models
Issue of 2021–12–05
five papers selected by
Joram Mooiweer, University of Groningen



  1. Lab Chip. 2021 Dec 01.
      The pathophysiology of several lymphatic diseases, such as lymphedema, depends on the function of lymphangions that drive lymph flow. Even though the signaling between the two main cellular components of a lymphangion, endothelial cells (LECs) and muscle cells (LMCs), is responsible for crucial lymphatic functions, there are no in vitro models that have included both cell types. Here, a fabrication technique (gravitational lumen patterning or GLP) is developed to create a lymphangion-chip. This organ-on-chip consists of co-culture of a monolayer of endothelial lumen surrounded by multiple and uniformly thick layers of muscle cells. The platform allows construction of a wide range of luminal diameters and muscular layer thicknesses, thus providing a toolbox to create variable anatomy. In this device, lymphatic muscle cells align circumferentially while endothelial cells aligned axially under flow, as only observed in vivo in the past. This system successfully characterizes the dynamics of cell size, density, growth, alignment, and intercellular gap due to co-culture and shear. Finally, exposure to pro-inflammatory cytokines reveals that the device could facilitate the regulation of endothelial barrier function through the lymphatic muscle cells. Therefore, this bioengineered platform is suitable for use in preclinical research of lymphatic and blood mechanobiology, inflammation, and translational outcomes.
    DOI:  https://doi.org/10.1039/d1lc00720c
  2. Lab Chip. 2021 Dec 01.
      Three-dimensional cell cultures using patient-derived stem cells are essential in vitro models for a more efficient and individualized cancer therapy. Currently, culture conditions and metabolite concentrations, especially hypoxia, are often not accessible continuously and in situ within microphysiological systems. However, understanding and standardizing the cellular microenvironment are the key to successful in vitro models. We developed a microfluidic organ-on-chip platform for matrix-based, heterogeneous 3D cultures with fully integrated electrochemical chemo- and biosensor arrays for the energy metabolites oxygen, lactate, and glucose. Advanced microstructures allow straightforward cell matrix integration with standard laboratory equipment, compartmentalization, and microfluidic access. Single, patient-derived, triple-negative breast cancer stem cells develop into tumour organoids in a heterogeneous spheroid culture on-chip. Our system allows unprecedented control of culture conditions, including hypoxia, and simultaneous verification by integrated sensors. Beyond previous works, our results demonstrate precise and reproducible on-chip multi-analyte metabolite monitoring under dynamic conditions from a matrix-based culture over more than one week. Responses to alterations in culture conditions and cancer drug exposure, such as metabolite consumption and production rates, could be accessed quantitatively and in real-time, in contrast to endpoint analyses. Our approach highlights the importance of continuous, in situ metabolite monitoring in 3D cell cultures regarding the standardization and control of culture conditions, and drug screening in cancer research. Overall, the results underline the potential of microsensors in organ-on-chip systems for successful application, e.g. in personalized medicine.
    DOI:  https://doi.org/10.1039/d1lc00689d
  3. J Pharm Sci. 2021 Nov 25. pii: S0022-3549(21)00640-7. [Epub ahead of print]
      The aim of this study was to develop an in vitro drug permeability methodology which mimics the gastrointestinal environment more accurately than conventional 2D methodologies through a three-dimensional (3D) Caco-2 tubules using a microphysiological system. Such a system offers significant advantages, including accelerated cellular polarization and more accurate mimicry of the in vivo environment. This methodology was confirmed by measuring the permeability of propranolol as a model compound, and subsequently applied to those of solifenacin and bile acids for a comprehensive understanding of permeability for the drug product in the human gastrointestinal tract. To protect the Caco-2 tubules from bile acid toxicity, a mucus layer was applied on the surface of Caco-2 tubules and it enables to use simulated intestinal fluid. The assessment using propranolol reproduced results equivalent to those obtained from conventional methodology, while that using solifenacin indicated fluctuations in the permeability of solifenacin due to various factors, including interaction with bile acids. We therefore suggest that this model will serve as an alternative testing system for measuring drug absorption in an environment closely resembling that of the human gastrointestinal tract.
    Keywords:  bile acids; organ-on-a-chip/microphysiological system (MPS); permeability; three-dimensional culture Caco-2 monolayer
    DOI:  https://doi.org/10.1016/j.xphs.2021.11.016
  4. Toxicol In Vitro. 2021 Nov 27. pii: S0887-2333(21)00202-2. [Epub ahead of print]79 105277
      Assessment of aerosols effects on liver CYP function generally involves aqueous fractions (AF). Although easy and efficient, this method has not been optimized recently or comparatively assessed against other aerosol exposure methods. Here, we comparatively evaluated the effects of the AFs of cigarette smoke (CS) and Tobacco Heating System (THS) aerosols on CYP activity in liver spheroids. We then used these data to develop a physiological aerosol exposure system combining a multi-organs-on-a-chip, 3D lung tissues, liver spheroids, and a direct aerosol exposure system. Liver spheroids incubated with CS AF showed a dose-dependent increase in CYP1A1/1B1, CYP1A2, and CYP2B6 activity and a dose-dependent decrease in CYP2C9, CYP2D6, and CYP3A4 activity relative to untreated tissues. In our physiological exposure system, repeated CS exposure of the bronchial tissues also caused CYP1A1/1B1 and CYP1A2 induction in the bronchial tissues and liver spheroids; but the spheroids showed an increase in CYP3A4 activity and no effect on CYP2C9 or CYP2D6 activity relative to air-exposed tissues, which resembles the results reported in smokers. THS aerosol did not affect CYP activity in bronchial or liver tissues, even at 4 times higher concentrations than CS. In conclusion, our system allows us to physiologically test the effects of CS or other aerosols on lung and liver tissues cultured in the same chip circuit, thus delivering more in vivo like data.
    Keywords:  Aerosol; Aqueous fraction; Cigarette smoke; Liver; Lungs; Multi-organs-on-a-chip; Xenobiotic metabolism
    DOI:  https://doi.org/10.1016/j.tiv.2021.105277
  5. J Neural Eng. 2021 Nov 29.
       OBJECTIVE: In this work we propose a method for producing engineered human derived three-dimensional neuronal assemblies coupled to Micro-Electrode Array (MEA) substrates for studying the electrophysiological activity of such networks.
    APPROACH: We used biocompatible chitosan microbeads as scaffold to build 3D networks and to ensure nutrients-medium exchange from the core of the structure to the external environment. We used excitatory neurons derived from human-induced Pluripotent Stem Cells (hiPSCs) co-cultured with astrocytes. By adapting the well-established NgN2 differentiation protocol, we obtained 3D engineered networks with good control over cell density, volume and cell composition. We coupled the 3D neuronal networks to 60-channel Micro Electrode Arrays (MEAs) to evaluate and monitor the functional activity of the neuronal population. In parallel, we generated two-dimensional neuronal networks to compare the results of the two models.
    MAIN RESULTS: 3D cultures were healthy and functional up to 42 Days In Vitro (DIVs). From the structural point of view, the hiPSC derived neurons were able to adhere to chitosan microbeads and to form a stable 3D assembly thanks to the connections among cells. From a functional point of view, neuronal networks showed spontaneous activity after a couple of weeks. We monitored the functional electrophysiological behavior up to 6 weeks and we compared the network dynamic with 2D models.
    SIGNIFICANCE: We presented for the first time a method to generate 3D engineered cultures with human-derived neurons coupled to MEAs, overcoming some of the limitations related to 2D and 3D neuronal networks and thus increasing the therapeutic target potential of these models for biomedical applications.
    Keywords:  3D network; brain-on-a-chip; electrophysiological activity; human-induced pluripotent stem cells; induced neuron; micro-electrodes arrays; network dynamics
    DOI:  https://doi.org/10.1088/1741-2552/ac3e02