bims-glumda Biomed News
on CGM data in management of diabetes
Issue of 2026–11–29
twenty-two papers selected by
Mott Given



  1. Zhonghua Yi Xue Za Zhi. 2026 Nov 24. 106(43): 4685-4694
      Continuous glucose monitoring (CGM) is a transformative and innovative technology that has shifted glucose monitoring from single-point measurements to continuous, dynamic, and visualized assessment. Over the past two decades, CGM has evolved from retrospective monitoring to real-time and intermittently scanned systems and subsequently to integration with automated insulin delivery systems. In parallel, a dynamic glucose assessment framework centered on time in range (TIR) has gradually been established. This CGM-centered framework has reshaped the paradigm of glycemic management. Meanwhile, the application of CGM is expanding beyond the assessment of glycemic control to the identification of risks of long-term adverse outcomes and the characterization of digital metabolic phenotypes, with the potential to support precision interventions for diabetes. This article reviews the evolution of CGM technology and its assessment framework, discusses its clinical applications in diabetes, pregnancy, inpatient care, and special populations, and examines current challenges, including technical standardization, insufficient evidence regarding long-term outcomes, and the underutilization of high-dimensional data. Future directions, including extended-wear and noninvasive sensors, multimodal monitoring, and artificial intelligence-driven precision medicine, are also discussed. The future value of CGM lies not simply in generating more data, but in translating continuous glucose data into clinically meaningful information that can improve clinical outcomes.
    DOI:  https://doi.org/10.3760/cma.j.cn112137-20260811-01968
  2. J Diabetes Sci Technol. 2026 Nov 27. 19322968261506228
       BACKGROUND: Cystic fibrosis-related diabetes (CFRD) is linked to adverse outcomes, yet early metabolic dysregulation may not be detected by conventional glycemic markers. Hemoglobin A1c has limited sensitivity in cystic fibrosis (CF), and oral glucose tolerance testing (OGTT), although recommended, is time-consuming. Continuous glucose monitoring (CGM) may provide novel dynamic metrics to improve dysglycemia identification.
    METHODS: In a prospective observational cohort, adults with CF underwent blinded CGM, OGTT, and HbA1c assessments. Analyses were based on baseline data from study visits conducted 3 months apart. Participants with insufficient CGM data were excluded, resulting in 67 individuals for analysis (normal glucose tolerance [NGT] n = 19, abnormal glucose tolerance [AGT] n = 21, CFRD n = 27). A glucose dynamic instability index (GDI) was derived from CGM time-series data. Diagnostic performance was assessed using receiver operating characteristic (ROC) analysis, with optimal thresholds identified by the Youden index.
    RESULTS: Median GDI increased progressively across glycemic categories (NGT: 627; AGT: 908; CFRD: 1941 mg2/dL2). The GDI demonstrated excellent discrimination of CFRD versus NGT (AUC 0.95; 95% CI, 0.89-1.00), with 85% sensitivity and 100% specificity at the optimal cutoff. Discrimination of CFRD versus non-CFRD was also strong (AUC 0.90; 95% CI, 0.82-0.98), while AGT versus NGT discrimination was moderate (AUC 0.74; 95% CI, 0.59-0.90). The GDI was used to derive an estimated CFRD risk score.
    CONCLUSIONS: A CGM-derived GDI differentiated glycemic categories in adults with CF and provided complementary information on glucose dynamic instability beyond conventional threshold-based CGM metrics. However, its value for CFRD risk stratification warrants further investigation.
    Keywords:  continuous glucose monitoring; cystic fibrosis; cystic fibrosis-related diabetes; early detection; glucose dynamics; risk stratification
    DOI:  https://doi.org/10.1177/19322968261506228
  3. JMIR Diabetes. 2026 Nov 20.
       BACKGROUND: Continuous glucose monitors (CGMs) from different manufacturers can read differently for the same person. Studies combining data across sensors can correct readings toward one sensor (the target) for comparability. However, it remains unclear how much reducing glucose error improves agreement on clinical endpoints such as time in range (TIR) and glucose zones. Sensor differences may also affect the consistency and accuracy of glycemic stage predictions.
    OBJECTIVE: To (1) compare Dexcom and FreeStyle Libre with each other and with capillary and laboratory glucose, (2) evaluate how well corrected readings match the target's glucose, TIR, and zones, and (3) assess whether richer CGM features improve cross-sensor diabetes stage classification without device identity.
    METHODS: In CGMacros, 45 adults, staged by glycated hemoglobin (15 healthy, 16 prediabetes, 14 type 2 diabetes [T2D]), simultaneously wore Dexcom G6 Pro and FreeStyle Libre Pro. Corrections used scaling, ridge regression, or a temporal convolutional network, fitted on other participants (population) or each person's first days (personalized) and tested on later days. We compared elastic net stage classifiers using 22 CGM features or mean glucose, with or without device identity, on both sensors in unseen participants.
    RESULTS: Libre averaged 32.37 mg/dL lower than Dexcom (95% CI 27.50-37.07). In matched samples, Dexcom averaged above and Libre below finger stick glucose (+16.51 and -14.33 mg/dL). External matched samples agreed in direction (Dexcom G6 in AI-READI, FreeStyle Libre H in ShanghaiT2DM). Libre showed 19.94 percentage points less TIR than Dexcom in healthy participants but 14.08 more in T2D. On Libre, TIR was higher in T2D than in healthy participants (82.33% vs 76.51%). Post hoc, one uniform shift of Dexcom readings could explain most of this opposite pattern. Toward Dexcom, personalized temporal ridge gave the lowest mean absolute error (10.73 mg/dL) and cut daily TIR error from 15.13 to 3.46 points, whereas personalized scaling detected zones better (balanced accuracy 77.9% vs 67.3%), at lower positive predictive value. Without device identity, a mean glucose model staged 30 of 45 participants differently across sensors; device identity reduced this to 13, and 22 CGM features without it to 12. Agreement did not imply correct staging. Neither model clearly discriminated better. Post hoc, adding these features to age, body mass index, and gender increased held-out discrimination in this exploratory internal evaluation (area under the curve gain 0.130; 95% CI 0.019-0.239, conditional on saved predictions).
    CONCLUSIONS: In exploratory analyses, these sensors were not interchangeable, and no correction was best for every endpoint. Because Dexcom averaged above and Libre below blood glucose in matched samples, correcting one toward the other improves comparability, not necessarily accuracy. Studies combining CGM data should name the target sensor and match the method to the endpoint: glucose values, glycemic zones, or glycemic stage.
    CLINICALTRIAL:
    DOI:  https://doi.org/10.2196/113658
  4. J Diabetes Sci Technol. 2026 Nov 24. 19322968261506329
       AIM OF STUDY: To assess the diagnostic accuracy between the next-generation, factory-calibrated continuous glucose monitoring (CGM) system and self-monitored blood glucose (SMBG) measurements, and to evaluate user experience with the system in Saudi children with diabetes.
    METHODS: We performed a diagnostic accuracy study of the next-generation Synchronized Artificial Intelligence System CGM system (Syai) more than 60 days. Sixty children aged 0 to 18 years with diabetes requiring insulin treatment wore the sensor on the upper arm, abdomen, thigh, or buttock for up to 14 days, followed by rotation to another site. Sensor performance was tested against SMBG. We reported the mean absolute relative difference (MARD) between CGM and SMBG measurement pairs, the proportion of CGM values meeting the 15/15, 20/20, and 30/30 agreement criteria.
    RESULTS: The mean age of the children was 9.0 ± 4.4 years, and 30 (50.0%) were men. The average diabetes duration was 2.7 ± 2.8 years, mean hemoglobin A1c was 9.1 ± 1.8%, and time in range (70-180 mg/dL) was 50.5 ± 19.6%. A total of 238 sensors were worn for 60 days, providing 2364 paired CGM-SMBG measurements for agreement analysis from 52 participants, including 1480 pairs from the upper arm, 585 from the abdomen, and 299 from the buttock/thigh. The overall pair-weighted MARD was 11.74% (participant-cluster bootstrap 95% CI, 10.79%-13.05%). The overall 15/15, 20/20, and 30/30 agreement rates were 76.44%, 86.29%, and 94.92%, respectively. No serious adverse events were reported.
    CONCLUSION: The Syai CGM system showed good accuracy with SMBG and a favorable user experience in this pediatric cohort.
    CLINICAL TRIAL REGISTRATION: Saudi Food and Drug Authority (SFDA) Clinical Trials Registry, http://www.sfda.gov.sa/en/node/3549755.
    Keywords:  CGM; MARD; accuracy; continuous glucose monitoring; pediatric diabetes; type 1 diabetes; usability
    DOI:  https://doi.org/10.1177/19322968261506329
  5. JMIR Diabetes. 2026 Nov 27.
       BACKGROUND: Distinguishing type 1 diabetes (T1D) from type 2 diabetes (T2D) guides treatment, but adult presentations overlap. Continuous glucose monitoring (CGM) captures day-to-day glucose patterns, but CGM studies differ in recruitment, treatment, and sensor manufacturer, complicating classifier evaluation.
    OBJECTIVE: We tested whether 7-day CGM features distinguish source-labeled T1D, T2D, and no diabetes in adults when entire datasets are held out, compared interpretable and neural models with simple baselines, and measured how sensor substitution changes predictions.
    METHODS: We trained models on 4 adult datasets (AI-READI, ShanghaiT2DM, T1DiabetesGranada, and T1DEXI) and tested them on 4 others (Glucotypes, ShanghaiT1DM, AZT1D, and CGMacros), with every T1D/T2D-by-Dexcom/Abbott combination in both partitions. A cap of 100 participants per dataset and diagnosis yielded 492 training and 107 test participants. Each 7-day window provided 47 CGM features; predictions were averaged within participant. We compared mean-glucose and clinical-summary (mean, standard deviation, coefficient of variation, and glucose zones) logistic regression with elastic net, boosted trees, and 4 neural networks. The primary end point was participant-level macro-averaged area under the receiver operating characteristic curve (AUROC) with bootstrap 95% CIs. In 29 CGMacros participants wearing Abbott FreeStyle Libre Pro and Dexcom G6 Pro sensors simultaneously, we substituted Dexcom for Libre input.
    RESULTS: Among the 107 test participants (37 with T1D, 18 with T2D, and 52 without diabetes), elastic net achieved a macro-AUROC of 0.943 (95% CI 0.914-0.969) and a T1D-versus-T2D AUROC of 0.935 (95% CI 0.869-0.980), exceeding mean-glucose and clinical-summary logistic regression (paired gains over the latter 0.046, 95% CI 0.015-0.079, and 0.105, 95% CI 0.017-0.212). Pooled mean glucose was similar (T1D-minus-T2D difference 5.28 mg/dL, 95% CI -1.24 to 11.40), whereas the mean of daily differences (MODD), the leading elastic-net feature, was higher in T1D (21.11 mg/dL, 95% CI 18.31-23.83). T1D sensitivity was 78.4% overall, 92% in AZT1D, and 50% in ShanghaiT1DM; T2D precision was 45.7%. No dataset contained both T1D and T2D; when the T1D-versus-T2D contrast came from the shared Shanghai registry and sensor, elastic-net AUROC was 0.82-0.86; the 47 features also separated 2 T1D Dexcom cohorts, T1DEXI and AZT1D (AUROC 0.998, 95% CI 0.994-1.000). Clinical-summary logistic regression led within Shanghai (0.907 vs 0.859) and in Abbott-only evaluation (0.976 vs 0.887). Substituting Dexcom for Libre input reduced primary elastic-net log loss by 0.389 (95% CI 0.140-0.673) but increased Abbott-only log loss by 0.567 (95% CI 0.257-0.923).
    CONCLUSIONS: In primary external testing, an interpretable 47-feature elastic-net model discriminated diabetes categories better than mean-glucose and clinical-summary baselines, with day-to-day glucose variability as the leading signal; because diagnosis and cohort coincided, this result may be optimistic. T1D errors concentrated in 1 adult-onset cohort, and sensor substitution changed predictions depending on the training setting, so classifiers pooling manufacturers should also be checked with paired-sensor recordings.
    CLINICALTRIAL:
    DOI:  https://doi.org/10.2196/113660
  6. Pharmacy (Basel). 2026 Nov 07. pii: 167. [Epub ahead of print]14(8):
      Continuous glucose monitoring (CGM) devices are becoming integral to diabetes care, and community pharmacists are well positioned to support patients using CGMs. However, limited training and time constraints may hinder integration of CGM services into community pharmacy practice. This study aimed to assess community pharmacists' confidence and identify barriers in practice to inform educational strategies and care model development. A cross-sectional survey was distributed electronically to community pharmacists practicing in Austin, Texas, USA. The survey included questions on CGM-related knowledge, counseling comfort, training experiences, and educational preferences, and responses were summarized using descriptive statistics. A total of 28 pharmacists completed this exploratory survey. Respondents expressed moderate comfort with basic CGM competencies, such as describing device components, but reported lower confidence in advanced tasks such as integrating CGM data with clinical teams. Key barriers to providing CGM counseling included limited time (64.3%) and lack of access to demonstration devices (60.7%). Most respondents indicated that wearing a CGM themselves would improve their counseling effectiveness. While community pharmacists recognize the value of CGM counseling, many feel underprepared due to time limitations and lack of practical training. Targeted education, hands-on exposure, and institutional support may be needed to expand the role of pharmacists in technology-enhanced diabetes care.
    Keywords:  community pharmacy; continuous glucose monitoring; cross-sectional survey; diabetes; pharmacist counseling; pharmacy education
    DOI:  https://doi.org/10.3390/pharmacy14080167
  7. Med Eng Phys. 2026 Nov 24.
      Continuous glucose monitoring (CGM) characterizes glycemic variability, but whether food log, contextual, and wrist sensor information can indicate a future participant relative excursion remains uncertain. We performed a retrospective feasibility analysis of the public PhysioNet BIG IDEAs Lab dataset: 16 participants with Dexcom G6 CGM, Empatica E4 streams, food logs, and demographic variables. PersLow, PersNorm, and PersHigh outcomes were defined from each participant's prior 24 hour CGM distribution; CGM was excluded from model predictors. Targets were matched at the exact clock time 30 minutes after prediction, and evaluation used leave-one-participant out folds with participant level uncertainty. The revised 87 variable full multimodal LightGBM model achieved mean participant macro F1 0.462 (95% bootstrap CI 0.424-0.499; median 0.488, IQR 0.410-0.518). A 39 variable food/context comparator achieved 0.443 (95% CI 0.409-0.476); the paired full-minus-comparator difference was +0.020 (95% CI 0.009-0.033). Removing explicit sensor missingness variables left predictions unchanged, and removing broader coverage proxies produced macro F1 0.465. A separate retrospective random-forest calibration analysis using personal CGM labels yielded common window macro F1 of 0.380 at 0 hours and 0.431 at 72 hours; this does not establish prospective personalization effectiveness. Most PersLow and PersHigh targets did not cross clinical glucose thresholds, and corrected event analyses retained nontrivial false alarm rates. The confidence intervals quantify participant variation conditional on the fitted analyses and do not account for the extensive model development and selection process. The small observed internal difference does not establish a clinically meaningful or externally generalizable wearable benefit. These exploratory findings do not establish glucose measurement, diagnosis, CGM free initialization, or prospective alerting.
    Keywords:  Continuous glucose monitoring; Food logs; Glycemic variability; Personalized glycemic excursions; Wearable sensors
    DOI:  https://doi.org/10.1088/1873-4030/aec5fa
  8. Healthcare (Basel). 2026 Nov 17. pii: 3944. [Epub ahead of print]14(22):
      Background/Objectives: Clinical and psychological factors associated with glycemic response to continuous glucose monitoring (CGM)-supported care remain incompletely understood in adults with long-standing type 2 diabetes (T2D) receiving intensive insulin therapy. This study examined their associations with six-month glycemic response in routine clinical practice. Methods: This prospective observational study included 225 adults initiating CGM alongside structured education and individualized treatment optimization at a tertiary diabetes center. Composite response was defined as an HbA1c reduction of ≥0.5 percentage points from baseline to six months and/or a time in range (TIR) increase of ≥10 percentage points between months three and six. Exploratory complete-case logistic regression examined clinical characteristics, three-month TIR, and baseline self-efficacy, motivation, and depressive symptoms. Results: Mean age was 66.1 ± 9.0 years, and baseline HbA1c was 8.54 ± 1.86%. The HbA1c response criterion was achieved by 91 of 146 participants (62.3%), and the TIR criterion by 32 of 147 (21.8%). Among 140 participants with evaluable composite outcomes, 97 (69.3%) were responders. Higher baseline HbA1c was associated with composite response (clinical model OR 5.40, 95% CI 2.68-10.88). Self-efficacy, motivation, and depressive symptoms showed no statistically significant associations in the adjusted model. Conclusions: Approximately seven in ten participants with evaluable outcomes achieved a composite glycemic response during CGM-supported care. Higher baseline HbA1c was associated with response, while the psychological measures assessed did not clearly distinguish responders after adjustment. These findings provide insight into response within a structured care pathway for adults with long-standing T2D receiving intensive insulin therapy and warrant confirmation in larger cohorts.
    Keywords:  continuous glucose monitoring; diabetes distress; glycated hemoglobin; insulin therapy; psychological factors; real-world study; self-efficacy; time in range; type 2 diabetes
    DOI:  https://doi.org/10.3390/healthcare14223944
  9. FASEB J. 2026 Dec 15. pii: e72522. [Epub ahead of print]40(23):
      Type 2 diabetes mellitus (T2DM) is a multisystem endocrine disorder that requires multidisciplinary management in solving its global health challenge, as its prevalence increases despite the scientific advances in therapeutic and dietary interventions. The management strategies are expected to be personalized rather than "one-size-fits-all", as their efficacy has declined over time. This occurred because of the often-overlooked significance of circadian rhythms, despite their physiological roles in energy balance, endocrine, and β-cell function. The misalignment of pharmaceutical interventions, nutrition, and lifestyle with the biological clock contributes to and complicates T2DM. The advent of Continuous glucose monitoring (CGM) has now enabled comprehensive assessment of glycemic variability over a long period, allowing monitoring of the impact of nutrition, physical activity, and therapy. CGM has been shown to improve the precision of therapeutic interventions in alignment with the physiological clock. This will potentially enhance efficacy, minimize adverse effects, and improve long-term metabolic outcomes. However, several articles have separately explored chronotherapeutic, chrononutrition, and lifestyle modification for T2DM management, without a clinically integrated framework. This review, from a translational perspective, integrates circadian rhythms, chronotherapeutic interventions, chronotyping, lifestyle factors, and gene variants associated with glycemic dysregulation to optimize T2DM management. A CGM-assisted multilayered chronotherapeutic algorithm was further proposed to support more personalized T2DM management and to guide prospective clinical validation and hypothesis-driven research.
    Keywords:  T2DM algorithm; chrononutrition; chronotherapeutics; circadian rhythm; continuous glucose monitoring (CGM); glucose homeostasis; type 2 diabetes
    DOI:  https://doi.org/10.1096/fj.202603064R
  10. Diabet Med. 2026 Nov 25. pii: e70541. [Epub ahead of print]
       AIMS: Continuous glucose monitoring (CGM) has made visible large numbers of hypoglycaemic episodes that people with type 1 diabetes (T1D) do not perceive, and the clinical significance of this sensor-detected hypoglycaemia (SDH) remains contested. We examine whether SDH is clinically meaningful, arguing that its significance is outcome-dependent.
    METHODS: We narratively synthesised evidence on the association between SDH and four outcomes-glucose counterregulation, severe hypoglycaemia, chronic complications, and quality of life-in adults with T1D, focusing on time below range and the Glycemia Risk Index (GRI) identified by searching MEDLINE, Embase and the Cochrane Library.
    RESULTS: For counterregulation, SDH is consequential: real-world time below 3.0 mmol/L is independently associated with an attenuated adrenaline response to subsequent hypoglycaemia. For severe hypoglycaemia, SDH carries genuine but conditional predictive value, informative mainly when combined with awareness status and the depth and variability of exposure. For chronic complications, composite metrics such as the GRI are associated with albuminuria, retinopathy, and cardiovascular autonomic neuropathy, but wherever the index has been decomposed, the driver is its hyperglycaemia rather than hypoglycaemia component. For quality of life, unperceived SDH has not been shown to independently impair daily functioning, which is associated instead with person-reported hypoglycaemia.
    CONCLUSIONS: SDH should be interpreted alongside hypoglycaemia awareness and the person's lived experience rather than in isolation, and recorded separately from person-reported hypoglycaemia in both clinical practice and trials.
    Keywords:  Glycemia Risk Index; continuous glucose monitoring; hypoglycaemia; hypoglycaemia awareness; quality of life; severe hypoglycaemia; time below range
    DOI:  https://doi.org/10.1111/dme.70541
  11. Metabolites. 2026 Nov 19. pii: 915. [Epub ahead of print]16(11):
      Background: Continuous glucose monitoring is usually summarized by mean glucose, variability, and time in range, which do not separate meal responses from between-meal drift. Methods: We analyzed 125 recordings from 112 adults with diabetes, holding 3470 meals with recorded times and weighed contents. Known meal times let baseline and meal response be estimated together from the whole trace, without a washout. Results: The fitted displacement was 32.9 mg/dL, peaking 105 min after the meal, against 45.4 mg/dL for the 120 min maximum rise and 27 to 35 for the excess over shuffled meal times. The response cleared 4.8 times faster than the baseline returned, rejecting the instantaneous jump in 100 of 117 recordings. Its assumed independent error failed in all 117 recordings. Allowing 90 min of memory returns a displacement 5 times smaller. On simulated recordings with that memory the first-order estimator recovers a true 45.0 mg/dL and a true 6.3 alike, while the longer-memory one turns negative, so the smaller figure measures the estimator. It does correct the half-time, 1.9 h against 6.7 h. Within patients the displacement rose with staple food mass, not meal weight. Conclusions: The parameters did not increase glycated hemoglobin prediction (change in R2 0.020, -0.035 to 0.084).
    Keywords:  Ornstein–Uhlenbeck process; continuous glucose monitoring; deconvolution; meal response; model misspecification; negative control; postprandial glucose; type 2 diabetes; weighed food records
    DOI:  https://doi.org/10.3390/metabo16110915
  12. BMC Pregnancy Childbirth. 2026 Aug 28. pii: 1363. [Epub ahead of print]26(1):
       BACKGROUND: Pregnant women with established risk factors, such as a family history of diabetes, advanced maternal age, and prepregnancy obesity, have an increased likelihood of developing gestational diabetes mellitus (GDM). Whether individualized intensive lifestyle management initiated in early pregnancy can reduce the occurrence of GDM in this high-risk population remains uncertain. This trial is designed to investigate the effectiveness of such an intervention in preventing GDM.
    METHODS: This investigator-initiated, multicenter, open-label, randomized controlled trial will recruit 346 pregnant women at high risk for GDM from three participating centers. Following written informed consent, participants will be allocated in a 1:1 ratio to either the intensive lifestyle intervention group or the control group. The primary endpoint is the diagnosis of GDM based on a 75-g oral glucose tolerance test performed between 24 and 28 weeks of gestation. Secondary endpoints include maternal and neonatal outcomes, maternal physical and psychological health, and body composition, all assessed through follow-up extending to six months after delivery.
    DISCUSSION: The study aims to compare an individualized intensive lifestyle intervention combined with continuous glucose monitoring (CGM) against standard prenatal care. We hypothesize that this intensive strategy will improve intervention adherence and thereby facilitate effective GDM prevention among high-risk pregnant women.
    TRIAL REGISTRATION NUMBER: ChiCTR2400091534. Registered on 30 October 2024.
    Keywords:  Continuous glucose monitoring; Gestational diabetes mellitus; High-risk pregnancy; Randomized controlled trial
    DOI:  https://doi.org/10.1186/s12884-026-09897-2
  13. J R Soc Interface. 2026 Nov 01. pii: 20260273. [Epub ahead of print]23(244):
      Understanding glucose regulation in type 2 diabetes requires modelling the nonlinear interactions among insulin dynamics, nutritional disturbances and physiological variability observed in free-living conditions. Classical minimal models provide important mechanistic insights into glucose-insulin regulation, but they are typically derived from controlled experimental settings and do not explicitly capture heterogeneous meal absorption processes. In this study, we develop a physiology-informed nonlinear modelling framework that extends the Bergman minimal model by incorporating a glycaemic-index-modulated disturbance term to represent temporally distributed carbohydrate absorption. The proposed formulation preserves the interpretability of physiological state variables while enabling subject-specific parameter identification using continuous glucose monitoring data and real-world dietary records. Model performance is evaluated on multi-day free-living datasets across multiple prediction horizons. Experimental results demonstrate that the proposed framework improves predictive stability and reduces forecasting error compared with the classical minimal model, with more pronounced advantages at longer horizons where delayed nutrient absorption and nonlinear system interactions dominate glucose dynamics. In addition, in silico insulin regulation experiments suggest favourable shifts in glucose control metrics under a fixed control policy. These findings indicate that incorporating nutritional quality modulation into physiological glucose models improves both predictive robustness and dynamical fidelity, providing a more realistic representation of glucose regulation in free-living type 2 diabetes.
    Keywords:  Bayesian optimization; continuous glucose monitoring; physiological mathematical model; type 2 diabetes mellitus
    DOI:  https://doi.org/10.1098/rsif.2026.0273
  14. Arch Endocrinol Metab. 2026 Nov 27. 70(6): e260138
       OBJECTIVE: To evaluate the impact of a remote multidisciplinary educational intervention combined with intermittently scanned continuous glucose monitoring (isCGM) on glycemic control in children and adolescents with type 1 diabetes mellitus followed at a public referral center in an upper-middle-income country that serves a socioeconomically vulnerable population.
    SUBJECTS AND METHODS: This prospective interventional study included 49 youth randomized to either a study group (SG), which received a six-month structured, telehealth-based multidisciplinary educational intervention delivered through a digital platform, or a control group (CG), which received conventional in-person follow-up. All participants initiated isCGM use from the third month onward. Socioeconomic, clinical, anthropometric, and laboratory data were collected on days 0, 90, and 180.
    RESULTS: Most participants belonged to low-income households (CG: 79.2%; SG: 80.0%). Mean HbA1c values remained above recommended targets in both groups throughout follow-up (CG: 9.2% on day 0 and 9.4% on day 180; SG: 9.1% on day 0 and 9.4% on day 180), with no significant between-group differences. After isCGM initiation on day 90, the SG showed a higher frequency of daily glucose scans and better time in range than the CG. Difficulties adhering to remote appointments were reported by 72% of SG participants and were associated with higher HbA1c levels.
    CONCLUSION: In youth with type 1 diabetes mellitus receiving care in a public health setting, telemedicine-based education combined with isCGM use was associated with improvements in selected glycemic metrics but not with reductions in HbA1c. Barriers related to adherence and digital access were frequent and may limit the effectiveness of remote interventions. Further studies with longer follow-up are warranted.
    Keywords:  Remote education; continuous glucose monitoring; telemedicine; type 1 diabetes mellitus
    DOI:  https://doi.org/10.20945/2359-4292-2026-0138
  15. Healthcare (Basel). 2026 Nov 16. pii: 3931. [Epub ahead of print]14(22):
       BACKGROUND/OBJECTIVES: Data describing glycemic changes after FreeStyle Libre (FSL) initiation in insulin-treated patients in Saudi Arabia are limited. We compared period-average HbA1c and hospital-recorded acute diabetes events (ADEs) during the 12 months before and after FSL initiation.
    METHODS: This single-center retrospective uncontrolled pre-post cohort included 202 individuals first prescribed FSL between February and July 2023 who had at least three post-initiation sensor dispensing/refill records and no documented discontinuation. The refill criterion selects participants based on follow-up behavior. HbA1c was averaged within each 12-month period.
    RESULTS: Among 202 participants (70 T1DM, 67 T2DM-MDI, 65 T2DM-Basal), mean HbA1c was 9.1 ± 1.9% before and 8.7 ± 1.8% after initiation (mean within-person change -0.44 percentage points, 95% CI -0.67 to -0.21; paired t-test p < 0.001). Within-group changes were -0.19 (p = 0.318), -0.58 (p = 0.009), and -0.55 (p = 0.008) percentage points in T1DM, T2DM-MDI, and T2DM-Basal, respectively. Between-group differences in change were not significant (ANOVA p = 0.316; Kruskal-Wallis p = 0.137); the common-slope ANCOVA group effect was nonsignificant (F[2, 198] = 1.58, p = 0.208), but the group × baseline HbA1c interaction was significant (F[2, 196] = 4.27, p = 0.015). Exploratory conditional pairwise contrasts at baseline HbA1c levels of 8%, 9% and 10% were not significant after multiplicity adjustment. Exploratory baseline-HbA1c strata were not multiplicity-adjusted and are vulnerable to regression to the mean. ADE counts were sparse.
    CONCLUSIONS: Lower mean HbA1c was observed after FSL initiation among selected patients, particularly in the two T2DM groups within-group; an independent FSL effect cannot be inferred without a comparator or treatment-change information.
    Keywords:  FreeStyle Libre; HbA1c; Saudi Arabia; continuous glucose monitoring; flash glucose monitoring; insulin-treated diabetes; real-world evidence; type 1 diabetes; type 2 diabetes
    DOI:  https://doi.org/10.3390/healthcare14223931
  16. J Clin Med. 2026 Nov 20. pii: 9113. [Epub ahead of print]15(22):
      Background: Physical activity is a cornerstone of type 1 diabetes (T1D) management and is associated with more favourable glycaemic outcomes. However, whether the relationship between physical activity and continuous glucose monitoring (CGM)-derived glycaemic metrics is similarly observed in individuals with and without cardiovascular autonomic neuropathy (CAN) remains unclear. We evaluated the association between self-reported physical activity levels and CGM-derived glycaemic metrics in adults with T1D according to CAN status. Methods: In this cross-sectional study, adults with T1D were evaluated for CAN according to Toronto Consensus criteria and for physical activity level using the International Physical Activity Questionnaire (IPAQ). CGM-derived metrics were analysed across physical activity levels separately in participants with and without confirmed CAN. Multivariable linear regression models were used to assess adjusted associations between physical activity and CGM-derived outcomes. Results: Of 90 participants, 15 (16.7%) had confirmed CAN and 75 (83.3%) had no confirmed CAN. Physical activity levels differed according to CAN status (p = 0.001), with lower physical activity more frequently observed in the confirmed CAN group. Confirmed CAN was also associated with lower time in range (TIR) (56.0% vs. 72.0%, p = 0.002) and higher time above range (TAR) (27.0% vs. 22.0%, p = 0.006), coefficient of variation (CV) (36.3% vs. 32.0%, p = 0.020), glucose management indicator (GMI) (7.4% vs. 7.1%, p = 0.030) and mean glucose (171 mg/dL vs. 157 mg/dL, p = 0.028). Among individuals without confirmed CAN, higher physical activity levels were associated with a more favourable CGM-derived profile, whereas no significant differences across physical activity levels were observed in those with confirmed CAN. In adjusted analyses, high versus low physical activity was associated with higher TIR (β = 15.22, p = 0.005), lower TAR (β = -7.60, p = 0.048), lower GMI (β = -0.77, p = 0.003) and lower mean glucose (β = -33.20 mg/dL, p = 0.002) in the no confirmed CAN group. Although interactions between high physical activity and CAN status were statistically significant in the primary analyses, sensitivity analyses combining moderate and high physical activity did not show significant interactions for any of these outcomes. Conclusions: Higher self-reported physical activity was associated with more favourable glycaemic metrics among participants without confirmed CAN. Although interactions between physical activity and CAN status were significant in the primary models and after adjustment for insulin treatment modality, they were not statistically significant when moderate and high physical activity were combined in sensitivity analyses. Larger prospective studies are needed to further investigate the relationship between physical activity, CAN, and glycaemic control in T1D.
    Keywords:  CGM-metrics; cardiovascular autonomic neuropathy; physical activity; type 1 diabetes
    DOI:  https://doi.org/10.3390/jcm15229113
  17. BMC Pediatr. 2026 Sep 04. pii: 1246. [Epub ahead of print]26(1):
       BACKGROUND: This study aimed to examine the association between life management skills and perceptions of diabetes technology use among children and adolescents with Type 1 diabetes.
    METHODS: This cross-sectional correlational study was conducted between February and May 2026 with 112 children and adolescents aged 10-18 years with Type 1 diabetes who were recruited consecutively from two public hospitals in Kahramanmaras, Türkiye. Data were collected using a Sociodemographic and Clinical Information Form, the Life Management Skills Scale for Children with Type 1 Diabetes, and the Diabetes Technology Scale. Descriptive analyses, group comparisons with effect-size estimates, Pearson correlation analyses with 95% confidence intervals (CIs), and multivariable linear regression were performed.
    RESULTS: The mean age of participants was 13.18 ± 2.47 years, and 52.7% were female. The mean total scores were 57.59 ± 8.97 for the Life Management Skills Scale and 94.20 ± 29.69 for the Diabetes Technology Scale. Perceptions of diabetes technology use were positively correlated with total life management skills (r=.553, 95% CI [0.409, 0.670], p<.001). Diabetes Management Knowledge differed according to paternal education level (F(3,108) = 3.281, p=.024, η²=0.084) and diabetic ketoacidosis history (H(2) = 6.967, p=.031, ε²=0.046), whereas Diabetes Technology Scale scores differed according to living arrangement (H(2) = 7.213, p=.027, ε²=0.048) and diabetic ketoacidosis history (H(2) = 7.097, p=.029, ε²=0.047). In the multivariable complete-case analysis (n = 97), Diabetes Technology Scale scores remained independently associated with total life management skills after adjustment for age, diabetes duration, HbA1c, insulin treatment regimen, and glucose monitoring method (B = 0.146, SE = 0.026, β = 0.496, 95% CI [0.094, 0.198], p<.001; R²=0.363).
    CONCLUSIONS: More positive perceptions of diabetes technology use were associated with higher life management skills after adjustment for measured demographic and clinical covariates. Because of the cross-sectional design, the temporal direction of this association cannot be determined, and the findings should not be interpreted as evidence of causality or intervention effectiveness.
    Keywords:  Adolescent; Child; Continuous Glucose Monitoring; Diabetes Mellitus, Type 1; Insulin Infusion Systems; Self-Management
    DOI:  https://doi.org/10.1186/s12887-026-07634-4
  18. J Funct Morphol Kinesiol. 2026 Nov 19. pii: 485. [Epub ahead of print]11(4):
       BACKGROUND AND OBJECTIVES: Regular exercise is an integral component of type 1 diabetes (T1D) care, yet its sustained practice is often limited by fear of hypoglycemia, uncertainty regarding insulin and carbohydrate adjustments, and the complexity of integrating exercise physiology with contemporary diabetes technology. This clinically oriented narrative review examines aerobic exercise in T1D within a preventive and rehabilitative framework, with emphasis on practical management in the era of continuous glucose monitoring (CGM) and automated insulin delivery (AID).
    METHODS: A structured PubMed/MEDLINE search was conducted across five prespecified domains: exercise physiology; insulin and carbohydrate adaptation; exercise-associated and nocturnal hypoglycemia; CGM and AID during physical activity; and cardiovascular, preventive, and rehabilitation-related outcomes.
    RESULTS: During aerobic exercise, the inability of exogenous insulin concentrations to fall as rapidly as endogenous insulin secretion creates a dynamic interaction among insulin on board, muscle glucose uptake, hepatic glucose production, carbohydrate availability, exercise characteristics, and counter-regulatory responses.
    CONCLUSIONS: Current evidence supports anticipatory, individualized strategies that combine exercise-related glucose targets, appropriate insulin adjustment, judicious carbohydrate intake, CGM trend interpretation, and post-exercise surveillance. Special attention is required for delayed and nocturnal hypoglycemia. Beyond acute glycemic management, sustained physical activity is associated with improved cardiorespiratory fitness, metabolic health, quality of life, and lower long-term cardiovascular risk. We propose exercise-based metabolic rehabilitation as a longitudinal, individualized approach that uses education, physiological understanding, and technology to support safe, confident, and sustained participation in physical activity. AID should therefore be viewed as a powerful component of, rather than a substitute for, personalized exercise management.
    Keywords:  automated insulin delivery; continuous glucose monitoring; exercise; metabolic rehabilitation; personalized management; physical activity; prevention; type 1 diabetes
    DOI:  https://doi.org/10.3390/jfmk11040485
  19. Cureus. 2026 Oct;18(10): e118292
      Automated insulin delivery (AID) systems integrate continuous glucose monitoring (CGM) with algorithm-driven insulin delivery and are increasingly used in children and adolescents with type 1 diabetes (T1D). However, the magnitude and consistency of glycemic benefit across pediatric age groups, together with the safety profile of these systems, warrant focused evaluation. We conducted a systematic review of randomized controlled trials evaluating AID systems in children and adolescents with T1D. PubMed/MEDLINE, Embase, Cochrane CENTRAL, and ClinicalTrials.gov were searched from inception through August 2026. Eligible studies compared AID with conventional insulin therapy or non-automated pump/CGM-based management and reported glycemic or safety outcomes. Risk of bias was assessed using the Cochrane Risk of Bias 2 tool. Findings were synthesized narratively without quantitative meta-analysis. Of 2,363 records identified, 11 randomized controlled trials met the eligibility criteria. Trials evaluated multiple AID platforms in participants aged 2-18 years, with intervention durations ranging from 12 to 104 weeks. AID consistently improved time in range ([TIR] 70-180 mg/dL). Individual trials reported TIR improvements ranging from approximately 7 to 12 percentage points. In one pediatric trial, TIR increased by 11 percentage points (95% CI, 7-14; P<0.001), while another demonstrated an 8.7-percentage-point increase (95% CI, 7.4-9.9; P<0.001) accompanied by a 0.4-percentage-point reduction in glycated hemoglobin. A six-month trial demonstrated a 6.7-percentage-point increase in TIR (95% CI, 2.7-10.8; P=0.002), with a concurrent 1.9-percentage-point reduction in time below range. Improvements were particularly pronounced during nighttime in several studies. Hyperglycemic exposure generally decreased, whereas hypoglycemia did not consistently increase. Severe hypoglycemia and diabetic ketoacidosis were uncommon, although the relatively small trial populations limited assessment of rare adverse events. Two trials were judged to have low overall risk of bias, while nine had some concerns; none was judged to have high risk of bias. AID systems consistently improve CGM-derived glycemic outcomes in children and adolescents with T1D, with the most reproducible benefit being increased TIR and reduced hyperglycemic exposure. Improvements in glycated hemoglobin were comparatively modest. Current randomized evidence does not demonstrate a consistent increase in hypoglycemia or diabetic ketoacidosis, although longer and larger studies are needed to characterize rare safety outcomes. AID should be regarded as an effective strategy for reducing glycemic burden rather than a fully autonomous treatment. Future research should emphasize long-term clinical and psychosocial outcomes, treatment burden, technology-related complications, and representation of diverse pediatric populations.
    Keywords:  adolescents; automated insulin delivery; children; continuous glucose monitoring; glycemic control; randomized controlled trials; time in range; type 1 diabetes
    DOI:  https://doi.org/10.7759/cureus.118292
  20. Biosensors (Basel). 2026 Nov 02. pii: 624. [Epub ahead of print]16(11):
      Microneedle (MN)-based optical biosensors are emerging as minimally invasive platforms for point-of-care testing (POCT) and wearable glucose monitoring by enabling direct access to interstitial fluid (ISF), which closely reflects plasma glucose dynamics. This review summarizes recent advances in MN-based glucose sensing with particular emphasis on optical biosensors. Blood-to-ISF glucose transport, physiological time lag, MN architectures, fabrication strategies, and ISF sampling mechanisms are discussed. Glucose recognition mechanisms are outlined together with optical transduction approaches, including colorimetric, fluorescence, surface-enhanced Raman scattering (SERS), photonic, and plasmonic sensing. Many colorimetric MN platforms currently function as single-use or endpoint POCT systems, whereas reversible fluorescence- and photonic-based sensors provide greater potential for repeated measurements and continuous glucose monitoring. Advanced functional materials, smartphone-assisted readout, and emerging artificial intelligence/machine-learning approaches for signal processing, calibration, and glucose prediction are also examined. Key analytical, mechanical, biocompatibility, and ex vivo/in vivo performance parameters are critically evaluated, together with patents, clinical investigations, and commercialization status. Compared with previous reviews that mainly address ISF sampling, general MN biosensing, glucose monitoring across multiple sensing modalities, or wearable optical sensors separately. This review provides an integrated glucose-specific framework linking ISF physiology, MN-mediated sampling, point-of-care and emerging continuous optical sensing, advanced materials, digital/AI analysis, performance validation, and clinical translation. Finally, current limitations involving biofouling, signal drift, long-term stability, manufacturing scalability, and clinical validation are discussed to highlight future directions toward advanced point-of-care platforms and emerging intelligent, wearable, and continuous glucose-monitoring systems.
    Keywords:  continuous glucose monitoring; glucose biosensors; interstitial fluid; microneedles; wearable biosensors
    DOI:  https://doi.org/10.3390/bios16110624
  21. Pharmaceutics. 2026 Nov 03. pii: 1420. [Epub ahead of print]18(11):
      Microneedles provide access to skin for peptide delivery and metabolic sensing, but insertion alone does not establish reliable treatment. This narrative review examines the evidence linking microneedle design to clinical claims in diabetes and identifies requirements for translation. Targeted literature retrieval distinguishes human delivery and sensing studies from animal and analytical experiments. Human hollow-microneedle studies show faster insulin absorption than subcutaneous administration, although improvement in primary glycemic outcomes is inconsistent. Responsive insulin and glucagon patches, incretin depots, and integrated sensing-delivery systems remain predominantly preclinical. Human sensing studies provide quantitative feasibility data, but accuracy depends on calibration, reference methods, population, and wear duration. We assess bioactive deposited dose separately from nominal loading, prospective decision accuracy separately from analytical agreement, and commanded delivery separately from verified exposure. Application mechanics, residual drug, local interference, manufacturing, and usability inform a proposed validation framework mapped to relevant standards and regulatory documents. This mapping is conceptual and does not constitute regulatory validation. The review identifies product-specific experiments needed to establish reproducible exposure, dependable measurements, and benefit against appropriate comparators. It does not infer human effectiveness from animal glucose lowering or assign one development pathway to all microneedle architectures.
    Keywords:  combination products; continuous glucose monitoring; diabetes mellitus; glucagon; interstitial fluid; intradermal insulin; ketone monitoring; microneedles
    DOI:  https://doi.org/10.3390/pharmaceutics18111420
  22. Diabetes Care. 2026 Nov 23. pii: dc262011. [Epub ahead of print]
       OBJECTIVE: To estimate the effect of enrollment in Unified Diabetes Care (UDC), an integrated digital care program, on care delivery, glycemic control, and longitudinal kidney biomarkers in type 2 diabetes.
    RESEARCH DESIGN AND METHODS: Using records from one tertiary diabetes center in China, we emulated monthly sequential target trials from 2016 to 2024. Each month, first UDC enrollment was compared with continued active specialist usual care among adults with type 2 diabetes, recent HbA1c, and active specialist contact. Eligibility was fixed at time zero regardless of later outcome availability. Overlap weighting and outcome models addressed measured baseline differences and differential follow-up measurement.
    RESULTS: A total of 33,845 patients contributed 38,796 emulated trial entries: monthly instances in which an eligible patient was assigned to first UDC enrollment or usual care. At 12 months, UDC was associated with lower HbA1c (difference -0.23 percentage points [-2.5 mmol/mol], 95% CI -0.29 to -0.18 [-3.2 to -2.0 mmol/mol]), greater HbA1c target attainment (+7.56 percentage points, 95% CI 5.47-9.65), and more regular follow-up (+6.39 percentage points). Relative differences in 1 + urinary albumin-to-creatinine ratio (UACR) were -16.2% at 6 months and -19.7% at 12 months; both remained significant after false discovery rate control. The exploratory 12-month estimated glomerular filtration rate (eGFR) difference was +0.56 mL/min/1.73 m2; main trajectory analyses showed later separation, while effect magnitude and precision varied across sensitivity analyses.
    CONCLUSIONS: UDC enrollment was associated with more continuous monitoring, sustained glycemic improvement, and lower UACR at 6 and 12 months. Small favorable eGFR differences emerged later, with their magnitude and precision varying across analytical specifications.
    DOI:  https://doi.org/10.2337/dc26-2011